The balloon is equipped with an automatic and/or manual lifting gas release device. The response pressure of an automatic pressure release device is established. The quantity of gas to be released by the pressure release device is large enough to prevent a further increase in pressure. Opening of a pressure relief device is unambiguously indicated to the operator.