(a) Fuel tank vents. Each fuel tank must be vented from the top part of the expansion space so that venting is effective under normal flight conditions. In addition:
(1) The vents must be arranged to avoid stoppage by dirt or ice formation;
(2) The vent arrangement must prevent siphoning of fuel during normal operation;
(3) The venting capacity and vent pressure levels must maintain acceptable differences of pressure between the interior and exterior of the tank, during:
(i) Normal flight operation;
(ii) Maximum rate of ascent and descent; and
(iii) Refuelling and defuelling (where applicable);
(4) Airspaces of tanks with interconnected outlets must be interconnected;
(5) There may be no point in any vent line where moisture can accumulate with the rotorcraft in the ground attitude or the level flight attitude, unless drainage is provided;
(6) No vent or drainage provision may end at any point:
(i) Where the discharge of fuel from the vent outlet would constitute a fire hazard; or
(ii) From which fumes could enter personnel compartments; and
(7) The venting system must be designed to minimise spillage of fuel through the vents to an ignition source in the event of a rollover during landing, ground operations, or a survivable impact.
(b) Carburettor vapour vents. Each carburettor with vapour elimination connections must have a vent line to lead vapours back to one of the fuel tanks. In addition –
(1) Each vent system must have means to avoid stoppage by ice; and
(2) If there is more than one fuel tank, and it is necessary to use the tanks in a definite sequence, each vapour vent return line must lead back to the fuel tank used for take-off and landing.
CS 29.975 specifies fuel tank vent and carburettor vapour vent requirements, including vent location, ice/dirt protection, siphon prevention, pressure control, and rollover spillage minimisation.