Navigate / EASA

CS 29.1395 Maximum intensities in overlapping beams of forward and rear position lights

ED Decision 2003/16/RM

No position light intensity may exceed the applicable values in the following table, except as provided in CS 29.1389(b)(3):

Overlaps

Maximum intensity

Area A (candelas)

Area B (candelas)

Green in dihedral angle L

10

1

Red in dihedral angle R

10

1

Green in dihedral angle A

5

1

Red in dihedral angle A

5

1

Rear white in dihedral angle L

5

1

Rear white in dihedral angle R

5

1


Where:

(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10° but less than 20°; and

(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20°.