Navigate / EASA

CS 29.1105 Induction system screens

ED Decision 2003/16/RM

If induction system screens are used:

(a) Each screen must be upstream of the carburettor;

(b) No screen may be in any part of the induction system that is the only passage through which air can reach the engine, unless it can be deiced by heated air;

(c) No screen may be deiced by alcohol alone; and

(d) It must be impossible for fuel to strike any screen.