ED Decision 2003/16/RM
Each oil tank must be designed and installed so that –
(a) It can withstand, without failure, any vibration, inertia, and fluid loads to which it may be subjected in operation; and
(b) It meets the requirements of CS 29.965, except that instead of the pressure specified in CS 29.965(b) –
(1) For pressurised tanks used with a turbine engine, the test pressure may not be less than 34 kPa (5 psi) plus the maximum operating pressure of the tank; and
(2) For all other tanks, the test pressure may not be less than 34 kPa (5 psi).