ED Decision 2021/016/R
VIBRATION HEALTH MONITORING
This AMC provides further guidance and acceptable means of compliance to supplement Federal Aviation Administration (FAA) Advisory Circular (AC) 29-2C, ยง AC 29.917. As such, it should be used in conjunction with the FAA AC.
This AMC clarifies the scope of complying with CS 29.1465, where the applicant uses vibration health monitoring as a compensating provision to meet CS 29.917(b).
Where vibration health monitoring is used as a compensating provision to meet CS 29.917(b), the competent authority should approve the design and performance of the vibration health monitoring system by requesting compliance with CS 29.1465(a).
[Amdt No: 29/5]