No position light intensity may exceed the applicable values in the following table, except as provided in CS 27.1389(b)(3):

Overlaps

Maximum intensity

Area A

(candelas)

Area B

(candelas)

Green in dihedral angle L

10

1

Red in dihedral angle R

10

1

Green in dihedral angle A

5

1

Red in dihedral angle A

5

1

Rear white in dihedral angle L

5

1

Rear white in dihedral angle R

5

1

 

Where:

(a)     Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10° but less than 20°; and

(b)     Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20°.