ED Decision 2023/013/R
ALTERNATIVE MAINTENANCE ACTIONS
‘Maintenance actions alternative to those referred to in point (c)(2)(b)’ refer to when the ICA issued by the DAH or the declarant of a declaration of design compliance are used as the basis for the AMP development and the CAMO, CAO or owner (as applicable), when developing the AMP, decides to deviate from certain of these instructions issued by the DAH or the declarant of a declaration of design compliance, introducing, for example, a less frequent interval than or a different task type (inspection instead of check) from the one established by the ICA.
These alternative maintenance actions shall not be less restrictive than those set out in the applicable MIP. This means that the extent of the maintenance to be covered by the deviating task cannot be less than the extent of the corresponding task in the MIP in terms of frequency and task type.
Examples of alternative maintenance actions:
ICA task |
AMP proposed alternative |
MIP task |
Alternative acceptable Yes/No |
Inspection XX 6 months interval |
Inspection XX 12 months interval |
Inspection XX 12 months interval |
Yes |
Inspection XX 12 months interval |
Inspection XX 24 months interval |
Inspection XX 12 months interval |
No |
Inspection XX 24 months interval |
Inspection XX 36 months interval |
Inspection XX 12 months interval |
No (24 months to be kept) |
Functional test system XX |
Operational test system XX (same interval) or general visual inspection system XX (same interval) |
Functional test system XX (same interval) |
No* |
Operational test system XX |
Functional test system XX (same interval) |
Operational test system XX (same interval) |
Yes*
|
Inspection XX 24 months interval |
Inspection XX 36 months |
None relevant |
Yes |
Functional test |
General visual inspection |
None relevant |
Yes |
*A functional test is considered more restrictive than an operational test.
Remark: the above does not apply to one-time interval extensions, for which ML.A.302(d)(1) provides 1-month or 10-h tolerance (i.e. permitted variation) for aeroplanes, touring motor gliders (TMGs) and balloons and 1-month tolerance for sailplanes and powered sailplanes other than TMGs.
Guidance on alternative maintenance actions in AMP development: deviations from ICA must not be less restrictive than the applicable MIP in frequency and task type, with examples and notes on one-time interval extensions
* Summary by Aviation.Bot - Always consult the original document for the most accurate information.
Loading collections...