ED Decision 2019/012/R
(a) General: A FATO should be surrounded by a
safety area which need not be solid.
(b) Characteristics:
(1) A safety area surrounding a FATO should
extend outwards from the periphery of the FATO for a distance of at least
3 m or 0.25 D, whichever is greater, of the largest helicopter the
FATO is intended to serve and:
(i) each external side of the safety area
should be at least 2 D where the FATO is quadrilateral (see Figure B-1);
or
(ii) the outer diameter of the safety area
should be at least 2 D where the FATO is circular.
(2) The surface of the safety area should be
treated to prevent flying debris caused by rotor downwash.
(3) When solid, the surface of the safety area
abutting the FATO should be continuous with the FATO.
(4) When solid, the surface of a safety area
should not project above a plane having an upward slope of 4 per cent,
commencing at the periphery of the FATO.
(5) From the outer edge of the safety area to
a distance of 10 m there should be a protected side slope rising at 45
degrees.
(6) The protected side slope should not be
penetrated by obstacles, except that when obstacles are located to one side of
the FATO only, they may be permitted to penetrate the side slope surface.
(7) No mobile object should be permitted on a
safety area during helicopter operations.
(8) No fixed object should be permitted above
the plane of the FATO on a safety area, except for frangible objects which,
because of their function, must be located on the area.
(9) Objects whose function requires them to be
located on the safety area should not:
(i) if located at a distance of less than
0.75 D from the centre of the FATO, penetrate a plane at a height of
5 cm above the plane of the FATO; and
(ii) if located at a distance of 0.75 D or more from the centre of the FATO, penetrate a plane originating at a height of 25 cm above the plane of the FATO and sloping upwards and outwards at a gradient of 5 per cent.
Figure
B-1. FATO and associated safety area
Helicopter landing area (FATO) safety regulations require a surrounding area extending at least 3 meters or 0.25D (helicopter size), up to 2D. This area must prevent debris, maintain specific slopes (4% and 45 degrees), and be free of mobile objects during operations. Fixed objects are restricted to frangible items.