CS
ADR-DSN.Q.851 Marking and lighting of wind turbines
ED Decision 2016/027/R
(a) Applicability: When considered as an obstacle a wind turbine should be marked and/or lighted.
(b) Marking: The rotor blades, nacelle and upper 2/3 of the supporting mast of wind turbines should be painted white, or if after a safety assessment, it is determined that other colour will improve safety.
(c) Lighting:
(1) Where lighting is deemed necessary for a single wind turbine or short line of wind turbines, the installation should be in accordance with paragraph (c)(2)(v) below, or as determined by a safety assessment.
(2) When lighting is deemed necessary in the case of a wind farm (i.e. a group of two or more wind turbines), the wind farm should be regarded as an extensive object and lights should be installed:
(i) to identify the perimeter of the wind farm;
(ii) respecting the maximum spacing, in accordance with CS ADR-DSN.Q.846(i), between the lights along the perimeter, or if after a safety assessment, it is determined that a greater spacing can be used;
(iii) so that, where flashing lights are used, they flash simultaneously throughout the wind farm;
(iv) so that, within a wind farm, any wind turbines of significantly higher elevation are also identified wherever they are located; and
(v) at locations prescribed in (i), (ii) and (iv):
(A) for wind turbines of less than 150 m in overall height (hub height plus vertical blade height), medium intensity lighting on the nacelle;
(B) for wind turbines from 150 m to 315 m in overall height, in addition to the medium intensity light installed on the nacelle, a second light serving as an alternate should be provided in case of failure of the operating light; the lights should be installed to assure that the output of either light is not blocked by the other;
(C) in addition, for wind turbines from 150 m to 315 m in overall height, an intermediate level at half the nacelle height of at least three low intensity Type E lights, as specified in CS ADR-DSN.Q.846(c), that are configured to flash at the same rate as the light on the nacelle; low-intensity Type A or B lights may be used if an safety assessment shows that low intensity Type E lights are not suitable.
(3) The obstacle lights should be installed on the nacelle in such a manner as to provide an unobstructed view for aircraft approaching from any direction.
[Issue: ADR-DSN/3]
Wind turbines, when considered aviation obstacles, must be marked and lighted for safety. Turbines should be painted white, unless another color improves visibility. Lighting is required on single turbines or wind farms, with specific intensity and placement based on turbine height and farm layout, ensuring unobstructed visibility for approaching aircraft.