AMC1 ADR.OPS.B.070(c)(5) Aerodrome works safety
ED Decision 2024/004/R
PROCEDURE FOR WORKSITE
ESTABLISHMENT AND RETURN TO OPERATIONAL USE
MARKING AND LIGHTING OF
UNSERVICEABLE AREAS
(a) The aerodrome operator should ensure that:
(1) unserviceability markers are displayed whenever any portion of
a taxiway, apron or holding bay is unfit for the movement of aircraft but it
is still possible for aircraft to bypass the area safely;
(2) on a movement area used at night, unserviceability lights
should be used;
(3) unserviceability markers and lights are placed at intervals
sufficiently close so as to delineate the unserviceable area. When lights are
used to mark temporary unserviceable areas at night or during reduced
visibility conditions, these lights should mark the extremities of the area. A
minimum of four such lights should be used, except where the area is
triangular in shape where a minimum of three lights may be used. The number of
lights should be increased when the area is large or of unusual configuration.
At least one light should be installed for each 7.5 m of peripheral
distance of the area. If the lights are directional, they should be orientated
so that, as far as possible, their beams are aligned in the direction from
which aircraft or vehicles will approach. Where aircraft or vehicles will
normally approach from several directions, consideration should be given to
adding extra lights or using omnidirectional lights to show the area from
these directions;
(4) unserviceability markers consist of conspicuous upstanding
devices such as flags, cones or marker boards;
(5) unserviceability markers and lights meet the specifications
described in CS ADR.DSN.R.870;
(6) existing markings leading into a worksite are masked or the
route is closed; and
(7) existing aeronautical ground lighting and signs leading into
the worksite are extinguished or masked on the movement area when used at
night or low visibility.
WORKSITE RETURN TO
OPERATIONAL USE
(b) The procedure for returning the worksite to operational use
should include at least the following:
(1) the removal from the worksite of personnel, vehicles, plants
and unserviceability lights and markers;
(2) the inspection of the affected areas for operational
serviceability including the condition of pavements, signs, lights and
markings, presence of FOD or surface contaminants such as dirt, sand, or loose
objects; and
(3) the notification of relevant authorities or affected
organisations, using suitable means of communication, including the
cancellation of relevant NOTAMs; and
(4) the use of appropriate checklists to record relevant actions.
RUNWAY PAVEMENT OVERLAYS
(c) The aerodrome operator should ensure that:
(1) when a runway is to be returned temporarily to an operational
status before resurfacing is complete, the longitudinal slope of the temporary
ramp, measured with reference to the existing runway surface or previous
overlay course, should be:
(i) 0.5 to 1.0 %for overlays up to and including 5 cm in
thickness; and
(ii) not more than 0.5 % for overlays more than 5 cm in
thickness.
(2) Before a runway being overlaid is returned to a temporary
operational status, a runway centre line marking, conforming to the applicable
specifications included in the aerodrome certification basis of the aerodrome,
should be provided.
(3) The location of any temporary threshold should be identified by
a 3.6-m wide transverse stripe.
Aerodrome operators must ensure safety during works, marking unserviceable areas with lights/markers, meeting specifications. Returning worksites to operational use requires removing equipment, inspecting surfaces, notifying authorities, and using checklists. Runway pavement overlays must adhere to slope limits, centerline markings, and temporary threshold identification.
* Summary by Aviation.Bot - Always consult the original document for the most accurate information.
Loading collections...