CAT.IDE.A.240 Supplemental oxygen –
non-pressurised aeroplanes
Regulation (EU) No 965/2012
Non-pressurised aeroplanes operated at pressure altitudes above 10 000 ft shall be equipped with supplemental oxygen equipment capable of storing and dispensing the oxygen supplies in accordance with Table 1.
Table 1
Oxygen minimum requirements for non-pressurised
aeroplanes
|
Supply for |
Duration and
cabin pressure altitude |
|
1.
Occupants of flight crew compartment seats on flight crew compartment duty
and crew members assisting flight crew in their duties |
The entire flying time at pressure altitudes
above 10 000 ft. |
|
2.
Required cabin crew members |
The entire flying time at pressure altitudes above
13 000 ft and for any period exceeding 30 minutes at pressure
altitudes above 10 000 ft but not exceeding 13 000 ft. |
|
3. Additional
crew members and 100 % of passengers(1) |
The entire flying time at pressure altitudes
above 13 000 ft. |
|
4.
10 % of passengers(1) |
The entire flying time after 30 minutes at
pressure altitudes above 10 000 ft but not exceeding
13 000 ft. |
|
(1)
Passenger numbers in Table 1 refer to passengers actually carried on board,
including persons younger than 24 months. |
|
Loading collections...