ED Decision 2022/005/R
OPERATIONAL PROCEDURES — PASSENGERS ON BOARD
In addition to AMC1 NCC.OP.157, for refuelling with passengers on board, operational procedures in the OM should specify that at least the following precautions are taken:
(a) the positioning of the helicopter and the corresponding helicopter evacuation strategy should be defined taking into account the wind as well as the refuelling facilities or vehicles;
(b) on a heliport, the ground area beneath the exits that are intended for emergency evacuation should be kept clear;
(c) an additional passenger briefing as well as instructions should be defined, and the ‘No smoking’ signs should be on unless ‘No smoking’ placards are installed;
(d) interior lighting should be set to enable identification of emergency exits;
(e) the use of doors during refuelling should be defined: doors on the refuelling side should remain closed, while doors on the opposite side should remain unlocked or, weather permitting, open, unless otherwise specified in the AFM;
(f) at least one suitable person capable of implementing emergency procedures for firefighting, communications, as well as for initiating and directing an evacuation, should remain at a specified location; this person should not be the qualified pilot at the controls or the person performing the refuelling; and
(g) unless passengers are regularly trained in emergency evacuation procedures, an additional crew member or ground crew member should be assigned to assist in the rapid evacuation of the passengers.
AMC2 NCC.OP.157 details operational precautions for helicopter refuelling with passengers on board, covering evacuation strategy, door use, lighting, briefings, and designated safety personnel.
* Summary by Aviation.Bot - Always consult the original document for the most accurate information.