AMC2 CAO.A.060(h) Maintenance standards

AMC2 CAO.A.060(h) defines independent inspection, qualifications for independent qualified persons, inspection performance points, and reinspection conditions for critical maintenance tasks.

Frequently Asked Questions

An independent inspection is an inspection performed by an 'independent qualified person' of a task carried out by an 'authorised person'. The 'authorised person' performs or supervises the task and assumes full responsibility for its completion in accordance with applicable maintenance data. The 'independent qualified person' attests to satisfactory completion and that no deficiencies have been found, but does not issue a CRS and is not required to hold certification privileges. The CRS is issued by the 'authorised person' after the independent inspection has been carried out satisfactorily.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The certificate of release to service (CRS) is issued by the 'authorised person' after the independent inspection has been carried out satisfactorily.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The training and experience could be demonstrated by: (i) holding a Part-66 licence in the same subcategory as the licence subcategory or equivalent necessary to release or sign off the critical maintenance task; or (ii) holding a Part-66 licence in the same category and specific training in the task to be inspected; or (iii) having received appropriate training and having gained relevant experience in the specific task to be inspected.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The independent inspection should ensure, for example, the correct assembly, locking and sense of operation of the parts involved. When inspecting control systems, the 'independent qualified person' should consider: (1) all parts of the system that have been disconnected or disturbed should be inspected for correct assembly and locking; (2) the system as a whole should be inspected for full and free movement over the complete range; (3) cables should be tensioned correctly with adequate clearance at secondary stops; (4) the operation of the control system as a whole should be observed to ensure controls operate in the correct sense; (5) if different control systems are interconnected, all interactions should be checked through the full range of applicable controls; and (6) software that is part of the critical maintenance task should be checked, for example, its version and compatibility with the aircraft configuration.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

In an independent inspection, the inspection is performed by an 'independent qualified person' who is different from the 'authorised person' performing the task. In a reinspection, the 'authorised person' performing the maintenance task is also acting as the 'independent qualified person' and performs the inspection.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

Reinspection should only be used in unforeseen circumstances when only one person is available to carry out the task and perform the independent inspection. The circumstances cannot be considered unforeseen if the person or organisation has not assigned a suitable 'independent qualified person' to that particular task.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The work card system should record the identification of each person, the date and the details of the independent inspection, as necessary, before the CRS is issued.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The work card system should record the identification of the 'authorised person' and the date and the details of the reinspection, as necessary, before the CRS is issued.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

EASA Logo
AMC2 CAO.A.060(h) Maintenance standards

ED Decision 2020/002/R

INDEPENDENT INSPECTION

Independent inspection is one possible error-capturing method.

(a) What is an independent inspection

An independent inspection is an inspection, which is performed by an ‘independent qualified person’, of a task carried out by an ‘authorised person’, taking into account that:

(1) the ‘authorised person’ is the person who performs the task or supervises the task, and assumes the full responsibility for the completion of the task in accordance with the applicable maintenance data;

(2) the ‘independent qualified person’ is the person who performs the independent inspection and attests to the satisfactory completion of the task, and that no deficiencies have been found. The ‘independent qualified person’ does not issue a certificate of release to service (CRS); therefore, he or she is not required to hold certification privileges;

(3) the CRS is issued by the ‘authorised person’ after the independent inspection has been carried out satisfactorily; and

(4) the work card system should record the identification of each person, the date and the details of the independent inspection, as necessary, before the CRS is issued.

(b) Qualifications of personnel performing independent inspections

The organisation should have procedures to demonstrate that the ‘independent qualified person’ has been trained and has gained experience in the specific control systems to be inspected. This training and experience could be demonstrated, for example, by:

(i) holding a Part-66 licence in the same subcategory as the licence subcategory or equivalent necessary to release or sign off the critical maintenance task; or

(ii) holding a Part-66 licence in the same category and specific training in the task to be inspected; or

(iii) having received appropriate training and having gained relevant experience in the specific task to be inspected.

(c) How to perform an independent inspection

The independent inspection should ensure, for example, the correct assembly, locking and sense of operation of the parts involved. When inspecting control systems that have undergone maintenance, the ‘independent qualified person’ should consider the following points independently:

(1) all those parts of the system that have actually been disconnected or disturbed should be inspected for their correct assembly and locking;

(2) the system as a whole should be inspected for full and free movement over the complete range;

(3) cables should be tensioned correctly with adequate clearance at secondary stops;

(4) the operation of the control system as a whole should be observed to ensure that the controls operate in the correct sense;

(5) if different control systems are interconnected so that they affect each other, all the interactions should be checked through the full range of the applicable controls; and

(6) software that is part of the critical maintenance task should be checked; for example, its version and its compatibility with the aircraft configuration.

(d) What to do in unforeseen cases when only one person is available

REINSPECTION

(1) Reinspection is subject to the same conditions as the independent inspection is, except that the ‘authorised person’ performing the maintenance task is also acting as ‘independent qualified person’ and performs the inspection.

(2) For critical maintenance tasks, reinspection should only be used in unforeseen circumstances when only one person is available to carry out the task and perform the independent inspection. The circumstances cannot be considered to be unforeseen if the person or organisation has not assigned a suitable ‘independent qualified person’ to that particular task.

(3) The CRS is issued by the ‘authorised person’ after the reinspection has been performed satisfactorily.

(4) The work card system should record the identification of the ‘authorised person’ and the date and the details of the reinspection, as necessary, before the CRS is issued.