CS 29.625 Fitting factors
Available versions for ERULES-1963177438-5545
ED Decision 2003/16/RM
found in: CS-29 Amdt 10 - Large Rotercraft (Jan 2023)
Select original version
...23)
...23)
Original Text
Select changed version
...23)
...23)
Changed text
Removed: 0
Added: 0
Unchanged: 0
Share
CS 29.625 Fitting factors ED Decision 2003/16/RM For each fitting (part or terminal used to join one structural member to another) the following apply: (a) For each fitting whose strength is not proven by limit and ultimate load tests in which actual stress conditions are simulated in the fitting and surrounding structures, a fitting factor of at least 1.15 must be applied to each part of: (1) The fitting; (2) The means of attachment; and (3) The bearing on the joined members. (b) No fitting factor need be used: (1) For joints made under approved practices and based on comprehensive test data (such as continuous joints in metal plating, welded joints, and scarf joints in wood); and (2) With respect to any bearing surface for which a larger special factor is used. (c) For each integral fitting, the part must be treated as a fitting up to the point at which the section properties become typical of the member. (d) Each seat, berth, litter, safety belt, and harness attachment to the structure must be shown by analysis, tests, or both, to be able to withstand the inertia forces prescribed in [CS 29.561(b)(3)](#_DxCrossRefBm1513259450) multiplied by a fitting factor of 1.33.
CS 29.625 Fitting factors ED Decision 2003/16/RM For each fitting (part or terminal used to join one structural member to another) the following apply: (a) For each fitting whose strength is not proven by limit and ultimate load tests in which actual stress conditions are simulated in the fitting and surrounding structures, a fitting factor of at least 1.15 must be applied to each part of: (1) The fitting; (2) The means of attachment; and (3) The bearing on the joined members. (b) No fitting factor need be used: (1) For joints made under approved practices and based on comprehensive test data (such as continuous joints in metal plating, welded joints, and scarf joints in wood); and (2) With respect to any bearing surface for which a larger special factor is used. (c) For each integral fitting, the part must be treated as a fitting up to the point at which the section properties become typical of the member. (d) Each seat, berth, litter, safety belt, and harness attachment to the structure must be shown by analysis, tests, or both, to be able to withstand the inertia forces prescribed in [CS 29.561(b)(3)](#_DxCrossRefBm1178331789) multiplied by a fitting factor of 1.33.