GM1 26.405 Cargo compartment fire protection
ED Decision 2024/010/R
INFORMATION ON HELICOPTER DESIGN CHARACTERISTICS ASSOCIATED WITH CARGO COMPARTMENT FIRE PROTECTION CAPABILITIES
The list below provides examples of the elements of information that may be made available to all known operators. Some of the examples may not apply since they depend on the helicopter type and on the type of cargo compartment. As deemed necessary, further detailed information may be included.
- cargo compartment characteristics, e.g.:
- location
- accessibility
- available volume
- smoke and fire detection systems’ features and capabilities, e.g. fire detection temperature
- fire-extinguishing, suppression and control systems’ features and capabilities, e.g.:
- location
- quantity
- handheld or built-in fire extinguisher
- type and quantity of fire-extinguishing agents
- fire suppression capability
- ventilation control systems’ features, e.g. shut-off capability during a fire event
- design characteristics to prevent the accumulation of harmful quantities of smoke, flames, extinguishing agents or noxious gases in other compartments;
- cargo compartment, floor, ceiling and sidewall liner panels features and capability, e.g.:
- material
- fire-resistance characteristics
- design and sealing of inaccessible compartments’ characteristics.
[Issue: 26/5]