CS 26.400 Fire extinguishers

EASA Logo

CS 26.400 Fire extinguishers

ED Decision 2020/023/R

Compliance with point 26.400 of Part-26 is demonstrated by complying with the following (see also GM1 26.400(b)):

(a) the extinguishing agent that is used in a built-in fire extinguisher for a lavatory waste receptacle or in a portable fire extinguisher for cabins and crew compartments must not be one of the agents that are listed in Annex A — Group II: Halons (halon 1211, halon 1301, and halon 2402) of ‘The Montreal Protocol on Substances that Deplete the Ozone Layer’, 8th Edition, 2009;

(b) the agent in any fire extinguisher must be acceptable, and be of a kind and in a quantity that is appropriate for the kinds of fire that are likely to occur where the extinguisher is intended to be used;

(c) any agent that is used in a personnel compartment or that is likely to enter a personnel compartment must be designed to minimise the hazard of a toxic gas concentration; and

(d) a discharge of the extinguisher must not cause any structural damage.

[Issue: 26/2]

[Issue: 26/3]

Frequently Asked Questions

CS 26.400(a) prohibits the use of halon 1211, halon 1301, and halon 2402, which are listed in Annex A -- Group II of the Montreal Protocol (8th Edition, 2009), in portable fire extinguishers for cabins and crew compartments.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

CS 26.400(a) requires that the extinguishing agent used in a built-in fire extinguisher for a lavatory waste receptacle must not be one of the agents listed in Annex A -- Group II: Halons (halon 1211, halon 1301, and halon 2402) of 'The Montreal Protocol on Substances that Deplete the Ozone Layer', 8th Edition, 2009.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

According to CS 26.400(b), the agent in any fire extinguisher must be acceptable, and be of a kind and in a quantity that is appropriate for the kinds of fire that are likely to occur where the extinguisher is intended to be used.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

CS 26.400(c) requires that any agent used in a personnel compartment or that is likely to enter a personnel compartment must be designed to minimise the hazard of a toxic gas concentration.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

CS 26.400(d) requires that a discharge of the extinguisher must not cause any structural damage.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

Compliance with point 26.400 of Part-26 is demonstrated by complying with the requirements in CS 26.400(a) through (d), which cover prohibited halons, appropriate agent selection, minimising toxic gas hazard, and preventing structural damage from discharge.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

No, CS 26.400(a) prohibits the use of halon 1301 (listed in Annex A -- Group II of the Montreal Protocol, 8th Edition, 2009) in built-in fire extinguishers for lavatory waste receptacles.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

CS 26.400(a) references 'The Montreal Protocol on Substances that Deplete the Ozone Layer', 8th Edition, 2009, specifically Annex A -- Group II, which lists halon 1211, halon 1301, and halon 2402.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation