CS 26.170 Fire extinguishers

EASA Logo

CS 26.170 Fire extinguishers

ED Decision 2020/023/R

Compliance with point 26.170 of Part-26 is demonstrated by complying with the following (see also GM1 26.170(b)):

(a) the extinguishing agent that is used in a built-in fire extinguisher for a lavatory waste receptacle or in a portable fire extinguisher for cabins and crew compartments must not be one of the agents that are listed in Annex A — Group II: Halons (halon 1211, halon 1301, and halon 2402) of ‘The Montreal Protocol on Substances that Deplete the Ozone Layer’, 8th Edition, 2009;

(b) the agent in any fire extinguisher must be acceptable, and be of a kind and in a quantity that is appropriate for the kinds of fire that are likely to occur in the compartment where the extinguisher is intended to be used;

(c) any agent that is used in a personnel compartment or that is likely to enter a personnel compartment must be selected to minimise the hazard of a toxic gas concentration; and

(d) a discharge of the extinguisher must not cause any structural damage.

[Issue: 26/2]

[Issue: 26/3]

Frequently Asked Questions

Compliance with CS 26.170 is demonstrated by complying with four conditions: (a) the extinguishing agent in built-in lavatory waste receptacle extinguishers or portable extinguishers for cabins and crew compartments must not be a Group II Halon (halon 1211, 1301, or 2402) as listed in Annex A of the Montreal Protocol 8th Edition 2009; (b) the agent must be acceptable, of a kind and quantity appropriate for the likely fires in the intended compartment; (c) any agent used in or likely to enter a personnel compartment must be selected to minimise toxic gas hazard; and (d) discharge must not cause structural damage.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

CS 26.170(a) prohibits the use of halon 1211, halon 1301, and halon 2402, which are listed in Annex A -- Group II: Halons of 'The Montreal Protocol on Substances that Deplete the Ozone Layer', 8th Edition, 2009.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

CS 26.170(a) prohibits the use of Group II halons in a built-in fire extinguisher for a lavatory waste receptacle or in a portable fire extinguisher for cabins and crew compartments.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

Under CS 26.170(b), the agent in any fire extinguisher must be acceptable, and be of a kind and in a quantity that is appropriate for the kinds of fire that are likely to occur in the compartment where the extinguisher is intended to be used.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

According to CS 26.170(c), any agent that is used in a personnel compartment or that is likely to enter a personnel compartment must be selected to minimise the hazard of a toxic gas concentration.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

CS 26.170(d) requires that a discharge of the extinguisher must not cause any structural damage.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

No, CS 26.170(a) explicitly prohibits the use of halon 2402 in portable fire extinguishers for cabins and crew compartments, as it is listed in Annex A -- Group II: Halons of the Montreal Protocol 8th Edition 2009.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The reference document is 'The Montreal Protocol on Substances that Deplete the Ozone Layer', 8th Edition, 2009, specifically Annex A -- Group II: Halons.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation