CS 26.160 Lavatory fire protection

EASA Logo

CS 26.160 Lavatory fire protection

ED Decision 2020/023/R

Compliance with point 26.160 of Part-26 is demonstrated by complying with CS 25.854, or equivalent or with the following:

(a) Each lavatory is equipped with a smoke detector system or equivalent that provides a warning light in the cockpit, or provides a warning light or audible warning in the passenger cabin that would be readily detected by a cabin crew member; and

(b) Each lavatory is equipped with a built-in fire extinguisher for each disposal receptacle for towels, paper, or waste, located within the lavatory. The extinguisher is designed to discharge automatically into each disposal receptacle upon occurrence of a fire in that receptacle.

[Issue: 26/3]

Frequently Asked Questions

Compliance with point 26.160 of Part-26 is demonstrated by complying with CS 25.854, or equivalent, or with the specific requirements in CS 26.160(a) and (b).

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

Each lavatory must be equipped with a smoke detector system or equivalent that provides a warning light in the cockpit, or provides a warning light or audible warning in the passenger cabin that would be readily detected by a cabin crew member.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

Each lavatory must have a built-in fire extinguisher for each disposal receptacle for towels, paper, or waste located within the lavatory. The extinguisher must be designed to discharge automatically into each disposal receptacle upon occurrence of a fire in that receptacle.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

Yes, compliance with CS 26.160 is demonstrated by complying with CS 25.854, or equivalent, or with the specific requirements in CS 26.160(a) and (b).

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The two acceptable compliance paths are: (1) complying with CS 25.854, or equivalent, or (2) complying with the specific requirements in CS 26.160(a) and (b) regarding smoke detection and built-in fire extinguishers for disposal receptacles.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The warning must be detectable either in the cockpit (warning light) or in the passenger cabin (warning light or audible warning) readily detected by a cabin crew member.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

The built-in fire extinguisher must be designed to discharge automatically into each disposal receptacle upon occurrence of a fire in that receptacle.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

Yes, each lavatory must be equipped with a built-in fire extinguisher for each disposal receptacle for towels, paper, or waste located within the lavatory.

* Aviation.Bot's Suggestion - Always consult the original regulation for confirmation

AI for Aviation Professionals

Aviation.Bot is an AI tool that assists you with aviation compliance.